Broken bags monitors 

A qualitative dust measurement, for example by triboelectric filter monitoring, includes both the monitoring of the clean gas dust content after dust collectors as well as the evaluation of the status of the exhaust gas cleaning systems.
The signal generation is based on the triboelectric measuring principle. In other words the charge exchange between the probe and the streaming as well as the bouncing dust particles is carried out.

According to the triboelectric measuring principle the filter monitoring device will be installed as in-situ measuring device in the clean gas pipes after the dust collectors. Devices are suitable for monitoring baghouse-, envelope- and cartridge filters and centrifugal separators (cyclones).
There are more than 10,000 pcs of Dr. Födisch AG filter monitor devices operating worldwide i.a. in the food processing or cement industries, in the metal- and woodworking and chemical industries.



Filter monitoring device PFM 14

  • filter monitor for in-situ dust measurement 
  • with separate operating unit
  • display showing the measured value in mg/m³ or line diagram
  • Zero and span calibration
  • CSA/UL 
  • EPA compliant MACT and Title V


Mobile filter diagnosis device PFM 14 K

  • mobile filter diagnosis device for triboelectric in-situ monitoring of dust emissions
  • measuring probe with variable length to  adapt to the local conditions
  • immediate clean gas dust content monitoring after the dust collectors
  • offline power supply by power bank
  • integrated recorder
  • Zero and span calibration
  • CSA/UL 
  • EPA compliant MACT and Title V


Filter monitoring device PFM 13

  • filter monitor for in-situ dust measurement 
  • compact device with display
  • suitable for the construction of filter monitoring systems
  • Zero and span calibration
  • CSA/UL 
  • EPA compliant MACT and Title V


Filter monitoring device PFM 13 C

  • filter monitor for in-situ dust measurement
  • compact device
  • suitable for the construction of filter monitoring systems
  • Zero and span calibration
  • CSA/UL
  • EPA compliant MACT and Title V


Filter monitoring device PFM 02

  • filter monitor for in-situ dust measurement 
  • compact device
  • display showing the measured value in mg/m³ or in line diagram
  • Zero and span calibration
  • CSA/UL
  • EPA compliant MACT and Title V


Filter monitoring device PFM 02 EX

  • filter monitor for in-situ dust measurement with EC-Type Examination Certificate (IBExU04ATEX1249 X)
  • approved for Ex II 1 / 3D Ex ia / tc IIIC T74 ° C Da / Dc and Ex II 3G Ex nA IIC T4 Gc ic
  • compact device
  • display showing the measured value in mg/m³ or in line diagram
  • Zero and span calibration
  • CSA/UL 
  • EPA compliant MACT and Title V


Residual dust sensor PFM 02 HB

  • residual dust sensor for wood processing industry with the EC-type examination certificate
  • compact device
  • suitable for the construction of filter monitoring systems
  • Zero and span calibration
  • CSA/UL 
  • EPA compliant MACT and Title V


Filter monitoring device PFM 92 C

  • filter monitor for in-situ dust measurement 
  • compact device consisting exclusively of the probe
  • suitable for the construction of filter monitoring systems
  • Zero and span calibration
  • CSA/UL 
  • EPA compliant MACT and Title V


Your needs – Our device

To submit you the convenient offer, please deliver insight into your requirements and service conditions on site. For this, please send us the following questionnaire in filled form:

Questionnaire [PDF]

Dr. Födisch Umweltmesstechnik AG

Zwenkauer Strasse 159

04420 Markranstädt

Germany

Phone:     +49 34205 755-0

Fax:          +49 34205 755-40

E-mail:     info@foedisch.de

Internet: www.foedisch.de

LinkedIn

 

 

 

Canada / USA Representation

CEM Specialties Inc.

1100 Dearness Drive, Unit 11

London, Ontario N6E 1N9

Canada

Phone:     +1-866-236-7732

E-mail:      sales@cemsi.ca

Internet:  www.cemsi.ca

LinkedIn